Gas Interlock Panel – Model GICS2601
Product Overview
Our new design Gas Interlock System is engineered to provide reliable, cost-effective, and fully compliant gas safety control for commercial kitchens and industrial environments. This unit complies with BS6173, ensuring your installation meets all UK safety standards.
What is a Gas Interlock System?
A gas interlock system (or gas safety shut-off system) is a mandatory safety mechanism in many commercial kitchens and gas-powered facilities. Its role is to prevent the release of hazardous gases by ensuring that:
- Gas appliances only operate when extraction fans are running.
- Gas flow is automatically shut off in the event of fan failure or unsafe operating conditions.
- Operators are alerted to unsafe conditions via both visual and audible alarms.
This prevents gas leaks, fires, and exposure to harmful fumes, protecting both staff and property.
How It Works
- Fan Current Monitoring: Built-in sensors continuously monitor the electrical current of canopy fans to verify operation. Differential Pressure Monitoring the pressure differential infront and behind the installed fans are measured via external pressure switches..
- Intelligent Control Panel: Processes input from fans and controls gas solenoid valve.
- Set Points: Adjustable fan current set points ensure appliances only run with sufficient airflow.
- Automatic Shut-Off: If fan speed drops below the set threshold, the system cuts off the gas supply via solenoid valves.
- Safety Alarms: Provides both visual indicators and audible warnings to alert staff immediately.
Key Features & Benefits
- Regulatory Compliance: Meets BS6173 and UKCA standards.
- Signal type: Current and Air Pressure sensing.
- Enhanced Safety: Prevents gas flow unless ventilation fans are operational.
- User-Friendly Design: LED indicators and an emergency stop button for quick action.
- Secure Access: Key-operated ON/OFF switch with mute function.
- Durable Construction: Robust enclosure for demanding environments.
Technical Specifications
- Model: GICS2601
- Voltage: 230V AC
- Indicators: Power, Gas On, EM Stop, Supply Fan, Extract Fan, Fan Fault, Service
- Emergency Stop: Large red push-button
- Control: Key-operated ON/OFF switch with mute
- Enclosure: IP-rated for commercial kitchen use
- Certification: UKCA | BS6173 compliant
- Dimensions: 120x120x65mm (LWH)
- Weight: 1.5kg
Applications
Perfect for:
- Commercial kitchens
- Catering facilities
- Restaurants and food preparation areas requiring gas interlock systems
Installation Examples
Installation by Richard Canary
Original: $250.03
-65%$250.03
$87.51Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Product Overview
Our new design Gas Interlock System is engineered to provide reliable, cost-effective, and fully compliant gas safety control for commercial kitchens and industrial environments. This unit complies with BS6173, ensuring your installation meets all UK safety standards.
What is a Gas Interlock System?
A gas interlock system (or gas safety shut-off system) is a mandatory safety mechanism in many commercial kitchens and gas-powered facilities. Its role is to prevent the release of hazardous gases by ensuring that:
- Gas appliances only operate when extraction fans are running.
- Gas flow is automatically shut off in the event of fan failure or unsafe operating conditions.
- Operators are alerted to unsafe conditions via both visual and audible alarms.
This prevents gas leaks, fires, and exposure to harmful fumes, protecting both staff and property.
How It Works
- Fan Current Monitoring: Built-in sensors continuously monitor the electrical current of canopy fans to verify operation. Differential Pressure Monitoring the pressure differential infront and behind the installed fans are measured via external pressure switches..
- Intelligent Control Panel: Processes input from fans and controls gas solenoid valve.
- Set Points: Adjustable fan current set points ensure appliances only run with sufficient airflow.
- Automatic Shut-Off: If fan speed drops below the set threshold, the system cuts off the gas supply via solenoid valves.
- Safety Alarms: Provides both visual indicators and audible warnings to alert staff immediately.
Key Features & Benefits
- Regulatory Compliance: Meets BS6173 and UKCA standards.
- Signal type: Current and Air Pressure sensing.
- Enhanced Safety: Prevents gas flow unless ventilation fans are operational.
- User-Friendly Design: LED indicators and an emergency stop button for quick action.
- Secure Access: Key-operated ON/OFF switch with mute function.
- Durable Construction: Robust enclosure for demanding environments.
Technical Specifications
- Model: GICS2601
- Voltage: 230V AC
- Indicators: Power, Gas On, EM Stop, Supply Fan, Extract Fan, Fan Fault, Service
- Emergency Stop: Large red push-button
- Control: Key-operated ON/OFF switch with mute
- Enclosure: IP-rated for commercial kitchen use
- Certification: UKCA | BS6173 compliant
- Dimensions: 120x120x65mm (LWH)
- Weight: 1.5kg
Applications
Perfect for:
- Commercial kitchens
- Catering facilities
- Restaurants and food preparation areas requiring gas interlock systems
Installation Examples
Installation by Richard Canary